S7-SoftPLC:cifX PROFIBUS® configuration via S7 for Windows®/STEP®7
User Interface
Use PROFIBUS® configuration from PLC
Takes the PROFIBUS® configuration created with S7 for Windows®/STEP®7. The bus will be configured and operated with these parameters from the PLC.
Enable PU/OP functions via PROFIBUS® DP
Allows a PU-communication via the PROFIBUS® to S7-SoftPLC. Some OP's (as e.g. OP3) use PU-communication for data exchange with the PLC, so that these panels can be used as well. 1)
Activate DPV-1 functions on the PROFIBUS®
Allows sending and receiving DPV1 functions to DPV1 slaves. SFB52 and SFB53 are available for DPV1 services.*
1) The bus configuration has to be created with S7 for Windows® hardware configuration or STEP®7 hardware configuration.
The configuration has to be created exclusively with General Station Description (GSD)
Settings
In the section [CIFX] PROFIBUS® specific settings are conducted. The settings are necessary, if the bus configuration is to be created with the S7 for Windows® hardware configuration or the STEP®7 hardware configuration.
Keyname | Value range | Default value | Description |
---|---|---|---|
B##C##SDBConf | 0 / 1 | 0 | Use PROFIBUS® configuration from PLC
0 = No, 1 = Yes |
B##C##DPV1Active | 0 / 1 | 0 | 1=Allows sending and receiving DPV1 functions to DVP1 slaves. SFB52 and SFB53 are available for DPV1 services. |
B##C##PBPGOPActive | 0 / 1 | 0 | 1=Allows a PU-communication via the PROFIBUS® to S7-SoftPLC. Some OP's (as e.g. OP3) use PU-communication for data exchange with the PLC, so that these panels can be used as well. |