S7-PCI315:Technical Data
From IBHsoftec Wiki English
Technical Data PLC
S7-PCI315 | |
---|---|
working memory | 256kB |
load memory | 256kB |
Remanent memory | entire memory |
Typical execution times | 0,200 µs/Instr. |
PU functions with STEP®7 or S7 for Windows® via MPI/PROFIBUS, via Ethernet using the ISO-On-TCP (RFC1006) or the IBHNet protocol. Alternatively the communication can take place via a virtual PC Adaptor.
Visualizations can connect via MPI/PROFIBUS, ISO-On-TCP (RFC1006), the IBHLink protocol or via the optional IBH OPCServer for visualization PC.
Technical Data Hardware
S7-PCI315 | |
---|---|
System Interface | PCI V2.3, 33 MHz |
Fieldbus | PROFIBUS |
LED | SYS, APL, COM0, COM1 |
Operating Elements | RUN/STOP Switch |
Battery Type | CR 2032 |
Memory Card | micro SD |
PROFIBUS Interface | DSub female Connector, 9 pin optically isolated RS-485 interface |
Power Supply | Rev 3:
5 V (4,5 ... 5,5 V), 500 mA |
External Power Supply | 18 ... 30 V DC |
Dimensions (L x W x D) | 120 mm x 90 mm 20 mm
130 x 121 x 22 mm over all |
Operating Temperatur | 0 ... 55 °C |
Protocols
Parameter | Description |
---|---|
Maximum number of supported DPV0/DPV1 slaves | 125 |
Maximum number of total cyclic input data | 3584 Bytes |
Maximum number of total cyclic output data | 3584 Bytes |
Maximum number of cyclic input data | 244 Bytes/Slave |
Maximum number of cyclic output data | 244 Bytes/Slave |
Configuration data | Max. 244 Bytes per slave |
Baud rate | Fixed values from 9,6 kBits/s to 12 MBit/s
Auto-detection mode is not supported |
Data transport layer | PROFIBUS FDL |
Limitations | DP V2 services are not implemented |