Difference between revisions of "S5/S7 for Windows:Handling of PLC backup archive files"

From IBHsoftec Wiki English
Jump to: navigation, search
(Created page with "Handling of PLC backup archive files xxx.arv with [http://www.ibhsoftec.com/IBH-Link-S7-PP_Eng IBHLink S7++] ==Time Synchronisation== The selected NTP(Network Time Protocol)...")
 
 
(14 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Handling of PLC backup archive files xxx.arv with [http://www.ibhsoftec.com/IBH-Link-S7-PP_Eng IBHLink S7++]  
+
Creating a project from PLC backup archive files '''xxx.arv''' with '''[http://www.ibhsoftec.com/S5W-Eng S5 for Windows®]''' or '''[http://www.ibhsoftec.com/57W-Eng S7 for Windows®]'''
==Time Synchronisation==
+
The selected NTP(Network Time Protocol) Server must be reachable.
+
  
[[Image:Settings_IBHLink.png‎‎|463px]]
+
The text below describes, how a project can be created with S5 for Windows®, if only a PLC backup archive file is available. For S7 PLCs with S7 for Windows® the procedure is similar.
 +
==Handling==
 +
The description how to make a '''PLC backup''' can be found within the <'''S5 for Windows® - Getting started'''> manual at page 52:
 +
 
 +
[[Image:Getting_started.png|437px]]
 +
 
 +
 +
Anyway, if only a '''xxx.arv''' file is available, a project can be generated this way:
 +
 
 +
Establish a connection to the Internal S5 PLC Simulation:
 +
 
 +
[[Image:Internal_S5_Sim.png|359px]]
 +
 
 +
By clicking on:
 +
 
 +
[[Image:Restore_online_blocks.png|380px]]
 +
 
 +
the archive file can be selected:
 +
 
 +
[[Image:Select_archive.png|541px]]
 +
 
 +
[[Image:Clear_reset.png|489px]]
 +
 
 +
After that all blocks are transferred to the Internal S5 PLC Simulation:
 +
 
 +
[[Image:Onilne_block_list.png|505px]]
 +
 
 +
Now a new STEP5 project can be created:
 +
 
 +
[[Image:New_Step5_Project.png|508px]]
 +
 
 +
By marking at least one block with the PLC Block List all blocks can be transferred to the PC:
 +
 
 +
[[Image:Transfer_Blocks.png|684px]]
 +
 
 +
[[Image:PC_Blocklist.png|909px]]

Latest revision as of 11:22, 19 September 2013

Creating a project from PLC backup archive files xxx.arv with S5 for Windows® or S7 for Windows®

The text below describes, how a project can be created with S5 for Windows®, if only a PLC backup archive file is available. For S7 PLCs with S7 for Windows® the procedure is similar.

Handling

The description how to make a PLC backup can be found within the <S5 for Windows® - Getting started> manual at page 52:

Getting started.png


Anyway, if only a xxx.arv file is available, a project can be generated this way:

Establish a connection to the Internal S5 PLC Simulation:

Internal S5 Sim.png

By clicking on:

Restore online blocks.png

the archive file can be selected:

Select archive.png

Clear reset.png

After that all blocks are transferred to the Internal S5 PLC Simulation:

Onilne block list.png

Now a new STEP5 project can be created:

New Step5 Project.png

By marking at least one block with the PLC Block List all blocks can be transferred to the PC:

Transfer Blocks.png

PC Blocklist.png