S7-PCI315:Instruction set
Contents
S7-PCI315 instruction set
The S7-PCI315 PLC has the complete instruction set of the SIMATIC® S7-315 PLC.
Bit logic instructions
Instruction | Operand | Description |
---|---|---|
A | AND with a scan to "1" | |
AN | AND with a scan to "0" | |
O | OR with scan to "1" | |
ON | OR with scan to "0" | |
X | Exclusive-OR with a scan to "1" | |
XN | Exclusive-OR with a scan to "0" | |
I | of an input | |
Q | of an output | |
M | of a memory flag | |
L | of a local data bit | |
T | of a timer | |
C | of a counter | |
DBX | of a data bit | |
DIX | of an instance data bit | |
==0 | result equal zero | |
<>0 | result unequal zero | |
>0 | result greater than zero | |
>=0 | result greater or equal zero | |
<0 | result less than zero | |
<=0 | result less or equal zero | |
UO | invalid result | |
OV | overflow | |
OS | Überoverflow (saved) | |
BR | binary result |
Other boolean logic instructions
Operation | Operand | Description |
---|---|---|
A( | AND left parenthesis | |
AN( | AND NOT left parenthesis | |
O( | OR left parenthesis | |
ON( | OR NOT left parenthesis | |
X( | Exclusive OR left parenthesis | |
XN( | Exclusive OR NOT left parenthesis | |
) | Right parenthesis | |
O | OR-ing AND operations | |
NOT | Negate RLO | |
SET | Set RLO to "1" | |
CLR | Set RLO to "0" | |
SAVE | Save RLO to the BR bit |
Operation | Operand | Description |
---|---|---|
= | Assign value of RLO | |
S | Set | |
R | Reset | |
FP | Positive edge detection | |
FN | Negative edge detection | |
I | of an input bit | |
Q | of an output bit | |
M | of a flag memory bit | |
L | of a local data bit | |
DBX | of a data bit | |
DIX | of an instance data bit |
Master Control Relay
Operation | Operand | Description |
---|---|---|
MCRA | Activate MCR | |
MCRD | Deactivate MCR | |
MCR( | Open MCR zone | |
)MCR | Close MCR zone |
Load / Transfer instructions
Operation | Operand | Description |
---|---|---|
L | Load operand | |
T | Transfer operand | |
IB | InpuInput byte | |
IW | Input word | |
ID | Input double word | |
QB | Output byte | |
QW | Output word | |
QD | Output double word | |
MB | Memory byte | |
MW | Memory word | |
MD | Memory double word | |
LB | Local data byte | |
LW | Local data word | |
LD | Local data double word | |
DBB | Data block byte | |
DBW | Data block word | |
DBD | Data block double word | |
DIB | Instance data block byte | |
DIW | Instance data block word | |
DID | Instance data block double word | |
STW | Status word | |
L | Const | Load constant value |
L | #Pointer | Load pointer |
L | T | Timer |
LC | T | Timer (BCD coded) |
L | C | Counter |
LC | C | Counter (BCD coded) |
L | DBNO | Data block number |
L | DBLG | Data block length |
L | DINO | Instance data block number |
L | DILG | Instance data block length |
Peripheral access instructions
Operation | Operand | Description |
---|---|---|
L | PIB | Load peripheral input byte |
L | PIW | Load peripheral input word |
L | PID | Load peripheral input double word |
T | PQB | Transfer peripheral output byte |
T | PQW | Transfer peripheral output word |
T | PQD | Transfer peripheral output double word |
Accumulator instructions
Operation | Operand | Description |
---|---|---|
PUSH | Push accumulators upwards | |
POP | Push accumulators downwards | |
ENT | Push accumulators (without A1) A2->A3, A3->A4 | |
LEAVE | Push accumulators (without A1) A4->A3, A3->A2 | |
TAK | Change ACCU1 with ACCU2 | |
CAW | Change ACCU1 bytes 0 and 1 | |
CAD | Change ACCU1 bytes 0 and 3, 1 and 2 |
Shift and rotating instructions
Operation | Operand | Description |
---|---|---|
SLW | Shift ACCU1-L left (word shift) | |
SLD | Shift ACCU1 left (double word shift) | |
SRW | Shift ACCU1-L right (word shift) | |
SRD | Shift ACCU1 right (double word shift) | |
SSI | Shift ACCU1-L right (word shift with sign) | |
SSD | Shift ACCU1 right (double word shift with sign) | |
RLD | Rotate ACCU1 left (double word) | |
RLDA | Rotate ACCU1 left through CC1 | |
RRDA | Rotate ACCU1 right through CC1 | |
RRD | Rotate ACCU1 right (double word) | |
Const | Number of places to shift/rotate | |
Number of places to shift/rotate located in ACCU2 |
Timer instructions
Operation | Operand | Description |
---|---|---|
SP | T | Start as impulse |
SE | T | Start as extended impulse |
SD | T | Start as ON-delay |
SS | T | Start as saving ON-delay |
SF | T | Start as OFF-delay |
R | T | Reset timer |
FR | T | Enable timer |
Counter instructions
Operation
Operand
Description
CU
C
Count up (increment)
CD
C
Count down (decrement)
S
C
Set counter
R
C
Reset counter
FR
C
Enable counter
Word instructions
Operation
Operand
Description
AW
AND ACCU1-L (AND word)
AD
AND ACCU1 (AND double word)
OW
OR ACCU1-L (OR word)
OD
OR ACCU1 (OR double word)
XOW
Exclusive-OR ACCU (XOR word)
XOD
Exclusive-OR ACCU (XOR double word)
Const
with a word or double word constant
with ACCU2
Arithmetic instructions
Operation
Operand
Description
==I
Integer values equal
<>I
Integer values unequal
>I
Integer values greater
>=I
Integer values greater or equal
<I
Integer values less
<=I
Integer values less or equal
==D
Double integer values equal
<>D
Double integer values unequal
>D
Double integer values greater
>=D
Double integer values greater or equal
<D
Double integer values less
<=D
Double integer values less or equal
==R
Real values equal
<>R
Real values unequal
>R
Real values greater
>=R
Real values greater or equal
<R
Real values less
<=R
Real values less or equal
SIN
Sine of a real value
COS
Cosine of a real value
TAN
Tangent of a real value
ASIN
Arcsine of a real value
ACOS
Arccosine of a real value
ATAN
Arctanget of a real value
SQR
Square a real value
SQRT
Square root a real value
EXP
e to the power of a real value
LN
Natural logarithm of a real value
+I
Integer addition
-I
Integer subtraction
- I
Integer multiplication
/I
Integer division
+D
Double integer addition
-D
Double-integer subtraction
- D
Double-integer multiplication
/D
Double-integer division
+R
Real addition
-R
Real subtraction
- R
Real multiplication
/R
Real division
MOD
Double integer division (modulo)
+
Const
Add a constant
+P#
Const
Add a pointer
DEC
decrement ACCU1-LL (one byte)
INC
increment ACCU1-LL (one byte)
Data type conversion instructions
Operation
Operand
Description
ITD
Convert integer to double integer
ITB
Convert integer to BCD
DTB
Convert double integer to BCD
DTR
Convert double integer to real
BTI
Convert BCD to integer
BTD
Convert BCD to double integer
RND
Convert real to double integer (round)
RND+
Convert real to double integer (round up)
RND-
Convert real to double integer (round down)
TRUNC
Convert real to double integer (truncate)
INVI
Invert ACCU1-L (integer)
INVD
Invert ACCU1 (double integer)
NEGI
Negate ACCU1-L (integer)
NEGD
Negate ACCU1 (double integer)
NEGR
Negate ACCU1 (real)
ABS
Absolute value (real)
Jump instructions
Operation
Operand
Description
JU
Destination
Jump unconditional
JC
Destination
Jump if RLO = 1
JCB
Destination
Jump if RLO = 1 (save RLO)
JCN
Destination
Jump if RLO = 0
JNB
Destination
Jump if RLO = 0 (save RLO)
JBI
Destination
Jump if BR = 1
JNBI
Destination
Jump if BR = 0
JZ
Destination
Jump if compare result = 0
JN
Destination
Jump if compare result ≠ 0
JP
Destination
Jump if compare result > 0
JPZ
Destination
Jump if compare result >= 0
JM
Destination
Jump if compare result < 0
JMZ
Destination
Jump if compare result <= 0
JUO
Destination
Jump if compare result "Unordered Math Instruction"
JO
Destination
Jump on overflow
JOS
Destination
Jump on saved overflow
JL
Destination
Jump distributor
LOOP
Destination
Loop programming (decrement ACCU1-L and jump if ≠ 0
Block call instructions
Operation
Operand
Description
CALL FB
Unconditional call of an FB with parameter transfer
CALL FC
Unconditional call of an FC with parameter transfer
CALL SFB
Unconditional call of an SFB with parameter transfer
CALL SFC
Unconditional call of an SFC with parameter transfer
UC FB
Unconditional call of an FB without parameter transfer
CC FB
Conditional call of an FB without parameter transfer
UC FC
Unconditional call of an FC without parameter transfer
CC FC
Conditional call of an FC without parameter transfer
BEU
End block unconditionally
BEC
End block conditionally (RLO = 1)
BE
End block
OPN
DB
Open data block
DI
Open instance data block
TDB
Exchange data block registers
Indirect adressing instructions
Operation
Operand
Description
LAR1
Load AR1
LAR2
Load AR2
MD
with memory double word
LD
with local data double word
DBD
with datablock double word
DID
with instance data block double word
LAR1
Load AR1 with ACCU1
LAR2
Load AR2 with ACCU1
LAR1
AR2
Load AR1 with AR2
LAR1
P#
Load AR1 with pointer
LAR2
P#
Load AR2 with pointer
TAR1
Transfer in AR1
TAR2
Transfer in AR2
MD
in memory double word
LD
in local data double word
DBD
in datablock double word
DID
in instance data block double word
TAR1
Transfer AR1 in ACCU1
TAR2
Transfer AR2 in ACCU1
TAR1
AR2
Transfer AR1 in AR2
TAR
Swap AR1 with AR2
+AR1
Add ACCU1 to AR1
+AR2
Add ACCU1 to AR2
+AR1
P#
Add pointer to AR1
+AR2
P#
Add pointer to AR2
Program display and null operation instructions
Operation
Operand
Description
NOP
0
Null operation instruction
NOP
1
Null operation instruction
BLD
Const
Program display instruction (null operation)