For the hardware configuration only the shown modules should be used. Configuring the process images will be made via the interface of the S7-SoftPLC . In the STEP® 7 hardware configuration only the Ethernet-CP parameters, the PROFIBUS® -CP parameters and the CPU parameters (like clock flags or time OBs) can be set.
Purchase order numbers compatible to S7-SoftPLC :
6ES7 315-1AF03-0AB0 V1.0
S7-SoftPLC 315 without PROFIBUS®
6ES7 315-2AG10-0AB0 V2.0
S7-SoftPLC 315 with PROFIBUS®
6ES7 315-2AG10-0AB0 V2.6
S7-SoftPLC 315 with PROFIBUS® and TIA
6ES7 315-2EH13-0AB0 V2.6
S7-SoftPLC 315 with PROFINET® and TIA
6ES7 416-1XJ02-0AB0 V1.0
S7-SoftPLC 416 without PROFIBUS®
6ES7 416-2XK02-0AB0 V1.1
S7-SoftPLC 416 with PROFIBUS®
6ES7 416-2XN05-0AB0 V5.1
S7-SoftPLC 416 with PROFIBUS® and TIA
6ES7 416-3ER05-0AB0 V5.1
S7-SoftPLC 416 with PROFINET® and TIA
Sample configuration for S7-SoftPLC 315
Slot
Order-No / Firmware
Name
2
6ES7 315-1AF03-0AB0 / V1.0
CPU 315
S7-SoftSPS 315 with Ethernet-CP
Slot
Order-No / Firmware
Name
2
6ES7 315-1AF03-0AB0 / V1.0
CPU 315
4
6GK7 343-1EX11-0XE0 / V2.0
CP 343-1
WARNING: SAVE CONFIGURATION DATA ON THE CPU NEEDS TO BE SELECTED.
S7-SoftPLC 315 with PROFIBUS®
Slot
Order-No / Firmware
Name
2
6ES7 315-2AG10-0AB0
CPU 315-2 DP
S7-SoftPLC 315 with PROFIBUS® and Ethernet-CP
Slot
Order-No / Firmware
Name
2
6ES7 315-2AG10-0AB0
CPU 315-2 DP
4
6GK7 343-1EX11-0XE0 / V2.0
CP 343-1
WARNING: SAVE CONFIGURATION DATA ON THE CPU NEEDS TO BE SELECTED.
S7-SoftPLC 416
Slot
Order-No / Firmware
Name
1
6ES7 405-0DA00-0AA0
PS 405 4A
2
6ES7 416-1XJ02-0AB0
CPU 416-1
S7-SoftPLC 416 with Ethernet-CP
Slot
Order-No / Firmware
Name
1
6ES7 405-0DA00-0AA0
PS 405 4A
2
6ES7 416-1XJ02-0AB0
CPU 416-1
3
6GK7 443-1EX11-0XE0 / V1.1
CP 443-1
S7-SoftPLC 416 with PROFIBUS®
Slot
Order-No / Firmware
Name
1
6ES7 405-0DA00-0AA0
PS 405 4A
2
6ES7 416-2XK02-0AB0
CPU 416-2 DP
S7-SoftPLC 416 with PROFIBUS® and Ethernet-CP
Slot
Order-No / Firmware
Name
1
6ES7 405-0DA00-0AA0
PS 405 4A
2
6ES7 416-2XK02-0AB0
CPU 416-2 DP
3
6GK7 443-1EX11-0XE0 / V1.1
CP 443-1