S7-SoftPLC:Visualizations

From IBHsoftec Wiki English
Revision as of 11:10, 19 December 2012 by Jonas (Talk | contribs)

Jump to: navigation, search

Direct drivers

The following list shows a choice of HMI manufacturers, who offer direct drivers for IBHsoftec S7-SoftPLC

Producer Programm S7-SoftPLC IBHNet RFC1006 Fetch/Write Modbus TCP
Copa-Data GmbH zenOn Yes No Yes Yes Yes
EXOR No No Yes Yes Yes
GEFASOFT AG München GraphPic® Yes Yes Yes Yes Yes
GTI-control Gesellschaft für technische Informationsverarbeitung GmbH PROCON-WIN No Yes Yes No Yes
ISIVIS No Yes Yes No Yes
INOSOFT AG VisiWinNET® Yes Yes Optional 1) Optional 1) Optional 1)
Lenze Digitec Controls GmbH VisiWinNET® (INOSOFT) Yes Yes Optional 1) Optional 1) Optional 1)
Pro-face No No Yes Yes Yes
Siemens ProTool® / Pro Yes Yes Yes Yes No
WinCC® / flexible Yes Yes Yes Yes Yes
Sütron TSwin.net No No Yes No Yes
zenOn (Copa-Data) Yes No Yes Yes Yes
Wonderware InTouch No No Yes No Yes

1) available on request at INOSOFT

IBHNet

The S7-SoftPLC can be accessed via the IBHNet driver, with every visualization software, that supports the IBHNet protocol. The IBHNet driver is available at http://www.ibhsoftec.com/ as free download.

If an HMI package has implemented an own direct driver for the IBH Link S7 (NetLink) protocol, it can access the S7-SoftPLC as well, since this protocol (NL_MPI) is supported by the S7-SoftPLC too.

In addition there is the possibility, that an own visualization (e.g. Visual® BASIC or other high level languages) can establish a communication via the IBHNet-object, which is installed with the IBHNet driver. Details on this are contained in the IBHNet documentation.

WARNING: USING WINCC THE OPTION "USE CYCLIC READ SERVICE OF PLC" IN "SYSTEM PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING PROTOOL THE OPTION "CYCLIC OPERATION" IN "PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING WINCC FLEXIBLE THE OPTION "CYCLIC OPERATION IN "CONNECTION"-DIALOGUE MUST NOT BE ACTIVATED

FOR FURTHER INFORMATION PLEASE CONSIDER THE IBHNET-HELP

RFC1006

To connect a HMI package to S7-SoftPLC via RFC1006 is possible, if the [[../Configuration/User_interface/cpx43.htm|Ethernet CP-343/443 emulation]] of the S7-SoftPLC has been started.

WARNING: USING WINCC THE OPTION "USE CYCLIC READ SERVICE OF PLC" IN "SYSTEM PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING PROTOOL THE OPTION "CYCLIC OPERATION" IN "PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING WINCC FLEXIBLE THE OPTION "CYCLIC OPERATION IN "CONNECTION"-DIALOGUE MUST NOT BE ACTIVATED

FOR FURTHER INFORMATION PLEASE CONSIDER THE IBHNET-HELP

Accessing S7-SoftPLC over PROFIBUS® with operator panels

The use of Hilscher PROFIBUS® Master Cards is required. The PROFIBUS® must be configured over MPI® like on an hardware PLC first. In the case of S7-SoftPLC this can happen directly, serially or via TCP/IP. If the PROFIBUS® is operational, the option "OnlineDP" can be activated in the driver configuration, to allow access to the S7-SoftPLC via PROFIBUS®.

WARNING: USING WINCC THE OPTION "USE CYCLIC READ SERVICE OF PLC" IN "SYSTEM PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING PROTOOL THE OPTION "CYCLIC OPERATION" IN "PARAMETER"-DIALOGUE MUST NOT BE ACTIVATED

USING WINCC FLEXIBLE THE OPTION "CYCLIC OPERATION IN "CONNECTION"-DIALOGUE MUST NOT BE ACTIVATED

FOR FURTHER INFORMATION PLEASE CONSIDER THE IBHNET-HELP

OPC Server

A connection to S7-SoftPLC from an HMI package with the IBHsoftec OPC server or other OPC servers, which support the mentioned protocols,is possible as well.