Difference between revisions of "OPCServer:Create Variables with Intouch FS Gateway"
From IBHsoftec Wiki English
Line 15: | Line 15: | ||
[[Image:FS gateway OPC Group Object eng.png|847px]] | [[Image:FS gateway OPC Group Object eng.png|847px]] | ||
:Within the filed '''<OPC Item ID Prefix>''' the name of the PLC can be entered, which was created within IBH OPC Editor f.e. '''PLC1''' followed by a dot. | :Within the filed '''<OPC Item ID Prefix>''' the name of the PLC can be entered, which was created within IBH OPC Editor f.e. '''PLC1''' followed by a dot. | ||
− | :Within the '''<Item>''' creation the notation ''<Access-path>''' is not necessary | + | :Within the '''<Item>''' creation the notation ''<Access-path>''' is not necessary.<br /> |
Revision as of 15:45, 29 October 2012
Create Variables with Intouch FS Gateway
To create Variables with Intouch FS Gateway with Intouch, please follow the description step by step.
- Start the ArchestrA System Management Console
- Start ⇒ Programme ⇒ Wonderware ⇒ System Management Console
- Add a OPC Node via <Add OPC Object> with the name IBH:
- As <Server Node> enter the IP Address of the PC , where the IBH OPC Server is running:
- As <Server Name> choose the IBH OPC Server:
- Add a OPC Group with the name OPC_Server:
- Within the filed <OPC Item ID Prefix> the name of the PLC can be entered, which was created within IBH OPC Editor f.e. PLC1 followed by a dot.
- Within the <Item>' creation the notation <Access-path> is not necessary.
- Starte the Intouch WindowMaker and create a new Acess name f.e. IBH_OPC :
- As <Node name> enter the IP Address of the PC , where the IBH OPC Server is running:
- As <Application name> enter FSGateway.
- The <Topic-Name> is the combination of Node name IBH and OPC Group name OPC_Server.
- Now the Variables can be created:
- Select the newly created access name IBH_OPC.
- The entry <Item> consists of :
<Access-Path>.<Item Name>.
- The <Access-Path> represents the name of the <PLC>, which has been created in the IBH OPC Editor.
- The <Access-Path> is not necessary in our sample, because it is aready defined within <OPC Item ID Prefix> .
- To access the variables which are already defined within the IBH OPC Editor the correct syntax is:
- Generic.<Variablenname>
- The configuration is now completed and the variables can be used: