It is possible to realize a connection from a PC with '''PcView''' to a SIMATIC® S5 station over ethernet using an IBHLink S7++ as gateway.
It is possible to realize a connection from a PC with '''PcVue''' to a SIMATIC S5 station over ethernet using an [http://www.ibhsoftec.com/IBH-Link-S5-PP-Eng IBHLink S5++] as gateway.


==Example==
==Example==
In the following example a configuration with '''PcView''' is shown.
In the following example a configuration with '''PcVue''' is shown.
The HMI station is connected to the IBHLink S5++ via an Ethernet connection. The IBHLink S5++ itself is connected to a SIMATIC® S5 station by the AS511 port. Bus parameters were configured by the IBHNet configuration tool.
The HMI station is connected to the IBHLink S5++ via an Ethernet connection. The IBHLink S5++ itself is connected to a SIMATIC S5 station on the AS511 port. Communication parameters were configured by the IBHNet configuration tool.


The following addresses were chosen in the example:
The following addresses were chosen in the example:
Line 17: Line 17:
|}
|}


MPI addresses:
'''Operation with S7 HMI devices:'''
For the operation with S7 HMI devices the following settings need to be made:  
{| class="wikitable"
{| class="wikitable"
|-
|-
! Station !! Address
| IP address of the PLC || IP address of the IBH Link S5++
|-
| Rack number of the PLC || 0
|-
|-
| IBHLink S5++ || 17
| Slot number of the PLC || 2
|-
|-
| S5- 115U station ||  
| MPI address of the PLC || 2
|}
|}
'''Operation with S7 HMI devices:'''
For the operation with S7 HMI devices the following settings need to be made:
IP address of the PLC = IP address of the IBH Link S5++
Rack number of the PLC = 0
Slot number of the PLC = 2
MPI® address of the PLC = 2
'''Configuration:'''
'''Configuration:'''


Line 41: Line 38:
By double clicking the line *CREATION* below <Node>:you can enter the IP address of the '''IBH Link S7++'''. <br />
By double clicking the line *CREATION* below <Node>:you can enter the IP address of the '''IBH Link S7++'''. <br />
As <Equipment type> please select '''S7300/400'''<br />
As <Equipment type> please select '''S7300/400'''<br />
[[Image:PcVue_node_parameter.png|412px]]<br />
[[Image:PcVue_node_parameter_S5.png|412px]]<br />
<br />
<br />
By double clicking the line *CREATION* below <Frame the needed variables can be choosen><br />
By double clicking the line *CREATION* below <Frame the needed variables can be choosen><br />

Latest revision as of 10:03, 19 September 2013

It is possible to realize a connection from a PC with PcVue to a SIMATIC S5 station over ethernet using an IBHLink S5++ as gateway.

Example

In the following example a configuration with PcVue is shown. The HMI station is connected to the IBHLink S5++ via an Ethernet connection. The IBHLink S5++ itself is connected to a SIMATIC S5 station on the AS511 port. Communication parameters were configured by the IBHNet configuration tool.

The following addresses were chosen in the example:

IP addresses:

Station Address
HMI station 192.168.10.122
IBHLink S5++ 192.168.10.102

Operation with S7 HMI devices: For the operation with S7 HMI devices the following settings need to be made:

IP address of the PLC IP address of the IBH Link S5++
Rack number of the PLC 0
Slot number of the PLC 2
MPI address of the PLC 2

Configuration:

The ethernet communication driver for S7-300/400 named SIEMENS IP ISO-S7 must be selected by double clicking the line *CREATION* below Network :



By double clicking the line *CREATION* below <Node>:you can enter the IP address of the IBH Link S7++.
As <Equipment type> please select S7300/400


By double clicking the line *CREATION* below <Frame the needed variables can be choosen>


After that the communication objects have to be activated by clicking on the buttons <ON< and <Validate>:


Within the Application Explorer you can add a Register:






The configuration is now completed and the variables/registers can be used: