	<entry>
		<id>https://wiki.ibhsoftec.com/en/index.php?title=S7-SoftPLC:NVRAM_configuration_with_the_user_interface&amp;diff=1107&amp;oldid=prev</id>
		<title>Jonas: Created page with &quot;none  &#039;&#039;&#039;Retain memory type:&#039;&#039;&#039;  Determines whether an ADS-TEC PCI-card or a file system is to be used.   &#039;&#039;&#039;Folder for Retain-File (no local dr...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/en/index.php?title=S7-SoftPLC:NVRAM_configuration_with_the_user_interface&amp;diff=1107&amp;oldid=prev"/>
		<updated>2013-01-23T07:13:07Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;&lt;a href=&quot;/en/index.php?title=File:Konf_NVRAM.png&quot; title=&quot;File:Konf NVRAM.png&quot;&gt;frame|none&lt;/a&gt;  &amp;#039;&amp;#039;&amp;#039;Retain memory type:&amp;#039;&amp;#039;&amp;#039;  Determines whether an ADS-TEC PCI-card or a file system is to be used.   &amp;#039;&amp;#039;&amp;#039;Folder for Retain-File (no local dr...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[[Image:Konf_NVRAM.png|frame|none]]&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Retain memory type:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Determines whether an ADS-TEC PCI-card or a file system is to be used.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Folder for Retain-File (no local drives):&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Path to retain data.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Write inteval (ms):&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Sequence, the remanent data is supposed to be saved in.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Priority:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Priority of the thread, that saves the data.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Status SFC Number:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Block number of the Status SFC.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Show Status SFC as FC&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Shows Status SFC as FC in &amp;#039;&amp;#039;S7-SoftPLC&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Remanent areas:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Areas that are being kept remanent&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
NOTE: THE AVAILABLE LENGHT OF RETAIN DATA DEPENDS ON THE VALUES SET IN THE S7 HARDWARE CONFIGURATION.&lt;/div&gt;</summary>