<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.ibhsoftec.com/en/index.php?action=history&amp;feed=atom&amp;title=S7-SoftPLC%3AConfiguring_TwinCAT_I%2FO_drivers</id>
	<title>S7-SoftPLC:Configuring TwinCAT I/O drivers - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.ibhsoftec.com/en/index.php?action=history&amp;feed=atom&amp;title=S7-SoftPLC%3AConfiguring_TwinCAT_I%2FO_drivers"/>
	<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/en/index.php?title=S7-SoftPLC:Configuring_TwinCAT_I/O_drivers&amp;action=history"/>
	<updated>2026-05-14T14:22:12Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.6</generator>
	<entry>
		<id>https://wiki.ibhsoftec.com/en/index.php?title=S7-SoftPLC:Configuring_TwinCAT_I/O_drivers&amp;diff=1007&amp;oldid=prev</id>
		<title>Jonas: Created page with &quot;none   &#039;&#039;&#039;Default&#039;&#039;&#039;  Resets the default values.   &#039;&#039;&#039;Don&#039;t stop fieldbus on PLC stop (only set outputs to 0&#039;&#039;&#039;  Instead of stopping the field...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/en/index.php?title=S7-SoftPLC:Configuring_TwinCAT_I/O_drivers&amp;diff=1007&amp;oldid=prev"/>
		<updated>2012-12-19T13:45:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;&lt;a href=&quot;/en/index.php?title=File:Konf_TwinCAT.png&quot; title=&quot;File:Konf TwinCAT.png&quot;&gt;frame|none&lt;/a&gt;   &amp;#039;&amp;#039;&amp;#039;Default&amp;#039;&amp;#039;&amp;#039;  Resets the default values.   &amp;#039;&amp;#039;&amp;#039;Don&amp;#039;t stop fieldbus on PLC stop (only set outputs to 0&amp;#039;&amp;#039;&amp;#039;  Instead of stopping the field...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[[Image:Konf_TwinCAT.png|frame|none]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Default&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Resets the default values.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Don&amp;#039;t stop fieldbus on PLC stop (only set outputs to 0&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Instead of stopping the fieldbus at PLC STOP completely, all outputs are set to 0.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Show TwinCAT SFCs as FCs&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Defines, whether blocks should be displayed as FCs or SFCs in &amp;#039;&amp;#039;S7-SoftPLC&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Show SFC 14/15&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Shows SFC 14/15.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Port Number (as defined in the Twincat System Manager)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Port number of the TwinCAT I/O task, normally 301.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Control SFC Number (additional Ports)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Block number of the Control SFC to read or write data from/to additional tasks.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;FB &amp;amp;quot;GetDeviceIdentification&amp;amp;quot; Number&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Block number of the FB &amp;amp;quot;GetDeviceIdentification&amp;amp;quot;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;FB &amp;amp;quot;AdsRead&amp;amp;quot; Number&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Block number of the FB &amp;amp;quot;AdsRead&amp;amp;quot;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;FB &amp;amp;quot;AdsWrite Number&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Block number of the FB &amp;amp;quot;AdsWrite&amp;amp;quot;.&lt;br /&gt;
&lt;br /&gt;
=== Load configuration from TwinCAT System Manager ===&lt;br /&gt;
&lt;br /&gt;
In order to avoid double documentation and to be able to reuse symbols, a converter exists, that allows to covert STEP&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;7 symbols from symbolic table (*.SEQ) data into I/O-tasks. And to inversely convert symbols from I/O-tasks into symbolic tables.&lt;br /&gt;
&lt;br /&gt;
Existing symbolic tables can be applied to existing tasks with multiple options.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Export symbolic tables out of the symbol editor with STEP&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;7.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* Open symbolic table in STEP&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;7 symbol editor.&lt;br /&gt;
* Select menu item &amp;amp;quot;Table -&amp;amp;gt; export&amp;amp;quot;.&lt;br /&gt;
* Select &amp;amp;quot;Allocation map (*.SEQ)&amp;amp;quot; format in the following dialogue.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Import symbolic tables with STEP&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;7 symbol editor.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* Open symbolic table in STEP&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;7 symbol editor.&lt;br /&gt;
* Select menu item &amp;amp;quot;Table -&amp;amp;gt; import&amp;amp;quot;.&lt;br /&gt;
* Select &amp;amp;quot;Allocation map (*.SEQ)&amp;amp;quot; format in the following dialogue.&lt;br /&gt;
* &amp;#039;&amp;#039;S7 for Windows&amp;#039;&amp;#039;&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt; projects generally work with SEQ files. Therefore a symbol file with the same name has to be generated, to be exchanged via the Windows&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt; Explorer, only.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Existing IO Tasks&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
In this window, I/O tasks and loaded System Manager files (.tsm) are displayed.&lt;br /&gt;
&lt;br /&gt;
By highlighting an I/O task, it is loaded, so that it can be exported into a symbolic table.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Open System Manager file&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Loads a System Manager file (.tsm) into the dialogue, to export the available symbols into a symbolic table.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Export into symbolic table&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Exports the loaded I/O task into a symbolic table (.seq).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Open symbolic table&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Loads a symbolic table (.seq) into the dialogue, to export the containing symbols into a I/O task.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Apply symbolic table to task&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Exports the loaded symbols into a System Manager file (.tsm.).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Content of symbolic table&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Shows the loaded symbols of a System Manager file (.tsm) or a symbolic table (.seq).&lt;br /&gt;
&lt;br /&gt;
=== Using a Beckhoff EtherCAT&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;-&amp;amp;gt;PROFIBUS&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt; coupler ===&lt;br /&gt;
&lt;br /&gt;
The Beckhoff EtherCAT&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;-&amp;amp;gt;PROFIBUS&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt; coupler has got a fixed 100ms-KBus-watchdog. Without this fixed setting the PROFIBUS&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt; would not clock correctly any more. Minimum cycle is &amp;amp;lt; 100ms, if BKs/KLs are used.&lt;br /&gt;
&lt;br /&gt;
That means there has to be one task, that is quicker than 100ms and has the highest priority, because the task with the highest priority triggers the PROFIBUS&amp;lt;sup&amp;gt;®&amp;lt;/sup&amp;gt;.&lt;/div&gt;</summary>