<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.ibhsoftec.com/en/index.php?action=history&amp;feed=atom&amp;title=IBHNet%3ATechnical_Data_IBH_Link_S7</id>
	<title>IBHNet:Technical Data IBH Link S7 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.ibhsoftec.com/en/index.php?action=history&amp;feed=atom&amp;title=IBHNet%3ATechnical_Data_IBH_Link_S7"/>
	<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/en/index.php?title=IBHNet:Technical_Data_IBH_Link_S7&amp;action=history"/>
	<updated>2026-05-15T21:19:54Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.6</generator>
	<entry>
		<id>https://wiki.ibhsoftec.com/en/index.php?title=IBHNet:Technical_Data_IBH_Link_S7&amp;diff=435&amp;oldid=prev</id>
		<title>Jonas: Created page with &quot; The &#039;&#039;&#039;&#039;&#039;IBH Link&#039;&#039;&#039;&#039;&#039; is an ethernet gateway. &#039;&#039;&#039;&#039;&#039;IBH Link&#039;&#039;&#039;&#039;&#039; fits in a DSub-housing. It consists of a complete fieldbus master together with a 10/100 MBit/s ethernet int...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/en/index.php?title=IBHNet:Technical_Data_IBH_Link_S7&amp;diff=435&amp;oldid=prev"/>
		<updated>2012-07-16T05:46:38Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot; The &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is an ethernet gateway. &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; fits in a DSub-housing. It consists of a complete fieldbus master together with a 10/100 MBit/s ethernet int...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
The &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is an ethernet gateway. &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; fits in a DSub-housing. It consists of a complete fieldbus master together with a 10/100 MBit/s ethernet interface which uses Auto-Negotiation to determine the speed of the network ist is connected to.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Due to the design in a D-Sub housing the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; can be directly attached on the fieldbus-connector of a MPI-capable device. The &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is connected to the next hub or switch by a 3m long STP-cable.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;If the &amp;#039;&amp;#039;IBH Link S7&amp;#039;&amp;#039;, &amp;#039;&amp;#039;IBH Link S5++&amp;#039;&amp;#039; or the &amp;#039;&amp;#039;IBH Link S7 Plus&amp;#039;&amp;#039; need to be connected directly to the PC, a crossed cable (Cross Over) may be required with older network cards. An &amp;#039;&amp;#039;IBH CX&amp;#039;&amp;#039;, &amp;#039;&amp;#039;IBH Link S7++&amp;#039;&amp;#039; and the &amp;#039;&amp;#039;IBH Link S7++ HS&amp;#039;&amp;#039; can always be used with a normal or a crossed cable.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
The &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is directly supplied over its MPI interface.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
The configuration takes place over ethernet. Therefore you have to start &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBHNet&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; on a PC which is connected to the same ethernet segment like the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
A diagnosis channel to the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is established over a defined TCP/IP port. The configuration is stored in a flash memory inside the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Drawing : ==&lt;br /&gt;
&lt;br /&gt;
[[Image:image042.jpg|frame|none|alt=IBHLink Drawing]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== MPI-Interface ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!pin!!signal!!explanation&lt;br /&gt;
|-&lt;br /&gt;
|1||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|2||DGND||reference potential&lt;br /&gt;
|-&lt;br /&gt;
|3||RxD/TxD-P||receive- / send-data-P&lt;br /&gt;
|-&lt;br /&gt;
|4||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|5||DGND||reference potential&lt;br /&gt;
|-&lt;br /&gt;
|6||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|7||VP||supply voltage 24 V&lt;br /&gt;
|-&lt;br /&gt;
|8||RxD/TxD-N||receive- / send-data-N&lt;br /&gt;
|-&lt;br /&gt;
|9||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
For the connection of the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; to the MPI interface of a Siemens S7 or another MPI-capable device no connection-cable is needed. The &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is directly attached on the MPI interface of the device.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
No external power supply is required, the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is supplied by the MPI interface.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;ATTENTION:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Due to its compact size, the &amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039; does not have a reverse voltage protection!&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Some PLCs may have a temporary error condition on the the MPI/Profibus for the startup period of the internal profibus chip, if the &amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039; is connected in an angular position. If the &amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039; needs to be connected to a PLC that reacts sensitive to this behaviour, the &amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039; must only be connected in powerless state of the PLC.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
== RJ45 connector ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!pin!!signal!!explanation&lt;br /&gt;
|-&lt;br /&gt;
|1||TX+||send-data&lt;br /&gt;
|-&lt;br /&gt;
|2||TX-||send-data&lt;br /&gt;
|-&lt;br /&gt;
|3||RX+||receive-data&lt;br /&gt;
|-&lt;br /&gt;
|4||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|5||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|6||RX-||receive-data&lt;br /&gt;
|-&lt;br /&gt;
|7||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|8||-||unused&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Connection with Hub/Switch ==&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;RJ45 connector&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
|style=&amp;quot;width:20em&amp;quot;| &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;IBH Link&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|style=&amp;quot;width:20em&amp;quot;| &amp;#039;&amp;#039;&amp;#039;Hub / Switch&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|style=&amp;quot;width:20em&amp;quot;| &amp;#039;&amp;#039;&amp;#039;PC&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[Image:image043.jpg|frame|none|alt=IBHLink schematic]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== LED Controls ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;RDY / RUN red&amp;#039;&amp;#039;&amp;#039;|| Flashing (1 Hz) ||Bootloader active&lt;br /&gt;
|-&lt;br /&gt;
|  || Flashing fast (10 Hz) || Booting, Firmware gets initialized&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;RDY / RUN green&amp;#039;&amp;#039;&amp;#039; || On || Ready, IP-Address set&lt;br /&gt;
|-&lt;br /&gt;
|  || Flashing irregular || no IP-Address or Address exists in the network&lt;br /&gt;
|-&lt;br /&gt;
|  || Flashing fast (10 Hz) || Firmware-Update in Progress&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;Link LED&amp;#039;&amp;#039;&amp;#039; || On || Connection to the ethernet is up&lt;br /&gt;
|-&lt;br /&gt;
|  || Off || No connection to the ethernet&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Technical Data ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Ethernet-Interface&amp;#039;&amp;#039;&amp;#039;||&lt;br /&gt;
|-&lt;br /&gt;
|speed||10 / 100 MBit/s&lt;br /&gt;
|-&lt;br /&gt;
|interface||10 / 100 Base-TX&lt;br /&gt;
|-&lt;br /&gt;
| ||Connector RJ45&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;PROFIBUS-Interface&amp;#039;&amp;#039;&amp;#039;||RS485, max 12 MBaud&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;PROFIBUS-Interface&amp;#039;&amp;#039;&amp;#039;||according to EN 50170&lt;br /&gt;
|-&lt;br /&gt;
|supply voltage||+24 V / 50 mA&lt;br /&gt;
|-&lt;br /&gt;
|operating temperature||0 °C - 50 °C&lt;br /&gt;
|-&lt;br /&gt;
|||IP 20&lt;br /&gt;
|-&lt;br /&gt;
|dimensions ||65 x 48 x 16 mm&lt;br /&gt;
|-&lt;br /&gt;
|weight ||~ 140 g with cable&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>