Before the field bus components can be accessed, they have to be configured. If no PROFIBUS® is used or the configuration can, because of other reasons, not be created with the S7 for Windows® hardware configuration or the STEP®7 hardware configuration, the cifX configuration must be created with the Hilscher SYCON.NET. If the default start addresses have not been changed via the special settings, the following assignments are valid.

The addresses of the digital peripheral are located in the cifX-address area of 0..511. Furthermore the following system parameters have to be set in the System Configurator Master Settings:


  • Controlled release of communication by the application program
  • Byte addresses
  • Little Endian (LSB-MSB)
  • Buffered, host controlled


Configuration - NETX-DPM[NETX 50DPM] - Master-Settings