<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="de">
	<id>https://wiki.ibhsoftec.com/de/index.php?action=history&amp;feed=atom&amp;title=IBHLink_S7%2B%2B%3AS7-300%2F400_WinCC_flexible</id>
	<title>IBHLink S7++:S7-300/400 WinCC flexible - Versionsgeschichte</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.ibhsoftec.com/de/index.php?action=history&amp;feed=atom&amp;title=IBHLink_S7%2B%2B%3AS7-300%2F400_WinCC_flexible"/>
	<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/de/index.php?title=IBHLink_S7%2B%2B:S7-300/400_WinCC_flexible&amp;action=history"/>
	<updated>2026-05-15T00:00:50Z</updated>
	<subtitle>Versionsgeschichte dieser Seite in IBHsoftec Wiki Deutsch</subtitle>
	<generator>MediaWiki 1.43.6</generator>
	<entry>
		<id>https://wiki.ibhsoftec.com/de/index.php?title=IBHLink_S7%2B%2B:S7-300/400_WinCC_flexible&amp;diff=2062&amp;oldid=prev</id>
		<title>Andreas am 16. Juli 2012 um 14:16 Uhr</title>
		<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/de/index.php?title=IBHLink_S7%2B%2B:S7-300/400_WinCC_flexible&amp;diff=2062&amp;oldid=prev"/>
		<updated>2012-07-16T14:16:35Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;de&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Nächstältere Version&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Version vom 16. Juli 2012, 14:16 Uhr&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l4&quot;&gt;Zeile 4:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Zeile 4:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Beispiel==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Beispiel==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Nachfolgend wird eine Beispielkonfiguration mit einer WinCC flexible Runtime dargestellt.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Nachfolgend wird eine Beispielkonfiguration mit einer WinCC flexible Runtime dargestellt.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Die HMI-Station ist hierzu mit einem IBHLink S7++ per Ethernet verbunden. Der IBHLink S7++ wurde per MPI bzw. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Porfibus &lt;/del&gt;DP an eine S7-300/400 angeschlossen und entsprechend über die IBHNet Konfigurationsoberfläche konfiguriert.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Die HMI-Station ist hierzu mit einem IBHLink S7++ per Ethernet verbunden. Der IBHLink S7++ wurde per MPI bzw. &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;PROFIBUS &lt;/ins&gt;DP an eine S7-300/400 angeschlossen und entsprechend über die IBHNet Konfigurationsoberfläche konfiguriert.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Folgende Adressen wurden gewählt:&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Folgende Adressen wurden gewählt:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Andreas</name></author>
	</entry>
	<entry>
		<id>https://wiki.ibhsoftec.com/de/index.php?title=IBHLink_S7%2B%2B:S7-300/400_WinCC_flexible&amp;diff=2051&amp;oldid=prev</id>
		<title>Andreas: Die Seite wurde neu angelegt: „ Der Aufbau einer HMI-Verbindung von einer WinCC flexible Runtime/Panel über Ethernet zu einer S7-300/400 Station kann über einen [http://www.ibhsoftec.com/I…“</title>
		<link rel="alternate" type="text/html" href="https://wiki.ibhsoftec.com/de/index.php?title=IBHLink_S7%2B%2B:S7-300/400_WinCC_flexible&amp;diff=2051&amp;oldid=prev"/>
		<updated>2012-07-16T11:53:15Z</updated>

		<summary type="html">&lt;p&gt;Die Seite wurde neu angelegt: „ Der Aufbau einer HMI-Verbindung von einer WinCC flexible Runtime/Panel über Ethernet zu einer S7-300/400 Station kann über einen [http://www.ibhsoftec.com/I…“&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Neue Seite&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
Der Aufbau einer HMI-Verbindung von einer WinCC flexible Runtime/Panel über Ethernet zu einer S7-300/400 Station kann über einen [http://www.ibhsoftec.com/IBH-Link-S7-PP IBHLink S7++] oder [http://www.ibhsoftec.com/IBH-Link-S7-PP-HS IBHLink S7++ HS] realisiert werden.&lt;br /&gt;
&lt;br /&gt;
==Beispiel==&lt;br /&gt;
Nachfolgend wird eine Beispielkonfiguration mit einer WinCC flexible Runtime dargestellt.&lt;br /&gt;
Die HMI-Station ist hierzu mit einem IBHLink S7++ per Ethernet verbunden. Der IBHLink S7++ wurde per MPI bzw. Porfibus DP an eine S7-300/400 angeschlossen und entsprechend über die IBHNet Konfigurationsoberfläche konfiguriert.&lt;br /&gt;
&lt;br /&gt;
Folgende Adressen wurden gewählt:&lt;br /&gt;
&lt;br /&gt;
IP-Adressen:&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Station !! Adresse&lt;br /&gt;
|-&lt;br /&gt;
| HMI-Station || 192.168.0.194&lt;br /&gt;
|-&lt;br /&gt;
| IBHLink S7++ || 192.168.0.167&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
MPI-/DP-Adressen:&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Station !! Adresse&lt;br /&gt;
|-&lt;br /&gt;
| IBHLink S7++ || 5&lt;br /&gt;
|-&lt;br /&gt;
| S7-300/400 Station || 12&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Konfiguration:&lt;br /&gt;
&lt;br /&gt;
Es ist zu beachten, dass in WinCC flexible der Ethernet-Kommunikationstreiber für S7 300/400 ausgewählt wird, da nur dieser eine Einstellung des Steckplatzes zulässt. Über die Einstellung des Steckplatzes wird angegeben, auf welche MPI- bzw. DP-Adresse die Verbindung aufgebaut werden soll. Siehe hierzu auch: [[Umrechnung MPI-Adresse]]&lt;br /&gt;
&lt;br /&gt;
[[Image:S7-200_WinCCflex.png|703px]]&lt;br /&gt;
&lt;br /&gt;
Falls die WinCC flexible Runtime verwendet wird, ist darauf zu achten, dass bei der Auswahl der PG/PC-Schnittstelle die korrekte Einstellung &amp;#039;&amp;#039;TCP/IP&amp;#039;&amp;#039; vorgenommen wird.&lt;br /&gt;
&lt;br /&gt;
[[Image:PGPC_Schnittstelle_TCPIP.png|412px]]&lt;br /&gt;
&lt;br /&gt;
Damit ist die Konfiguration der Verbindung abgeschlossen und es können wie gewohnt Variablen definiert werden.&lt;/div&gt;</summary>
		<author><name>Andreas</name></author>
	</entry>
</feed>